HIOKI 3198 MANUAL PDF

Quick Links. Download this manual See also: Manual. Instruction Manual. Table of Contents. Page 5 Contents Page 6 Contents

Author:Brarisar Kigashicage
Country:Brunei Darussalam
Language:English (Spanish)
Genre:Relationship
Published (Last):14 August 2004
Pages:223
PDF File Size:2.95 Mb
ePub File Size:2.95 Mb
ISBN:516-5-37379-934-6
Downloads:36472
Price:Free* [*Free Regsitration Required]
Uploader:Goltirisar



Hioki portable power meters and analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. The new and improved PQ is a power quality analyzer for monitoring and recording power supply anomalies, allowing their causes to be quickly investigated, and also for assessing power supply problems such as voltage drops, flicker, harmonics, and other electrical issues.

New features include the ability to drive current sensors straight from the PQA and enhanced recording capabilities. Select from Value Kits for added savings.

The critical importance of electrical power in today's society necessitates daily maintenance and management to ensure that problems don't occur. When they do, for example due to an equipment failure or abrupt surge in demand, engineers face the need to analyze the cause quickly. Capture the full range of power supply anomalies, including momentary interruptions, voltage drops, and frequency fluctuations, while recording trends to help investigate the causes of unexpected equipment malfunctions and sudden stoppages.

Record fluctuations in voltage, current, power, harmonics, and flicker when connecting a highly variable system such as a renewable energy source or EV charging station to the grid. Since the sensors are powered by the instrument, there's no need to set up a separate power supply. The PQ and PQ can measure all parameters at once, including power, harmonics, and anomaly waveforms.

When an event occurs, the instrument records the instantaneous waveform for 0. Triggers can be set for all event parameters in parallel, and you can check recorded data on the display while measurement is in progress. As a result, it can perform standard-mandated measurement tasks such as gapless, continuous calculation; detection of events such as swells, dips, and interruptions; and time synchronization using GPS optional. Class A Part of the IEC international standard, Class A defines power quality parameters, accuracy, and standard compliance to facilitate the comparison and discussion of measurement results from different instruments.

The PQ can measure transient voltages of up to V lasting as little as 0. It can also measure high-order harmonic components from 2 kHz to 80 kHz. As inverters enter into widespread use, malfunctions and failures in that frequency band are becoming more common. Since the PQ's fourth voltage channel is isolated from its first three voltage channels, the instrument can measure power and efficiency across two separate circuits. For example, you can verify the quality of the input AC and output DC of an EV rapid charger while simultaneously measuring power and efficiency between input and output.

The PQ can measure the secondary side of inverters with a fundamental frequency of 40 to 70 Hz and a carrier frequency of up to 20 kHz.

Since you can switch the display to show all measurement parameters while measurement is underway, it's easy to check conditions. Simply connect current sensors, touch "Sensor" on the screen, and the instrument will automatically detect sensor types and maximum current ranges. Simply choose the preset that suits your application, and the instrument will automatically configure the recording parameters. This capability eliminates any time difference between instruments to allow analysis that preserves the simultaneity of phenomena measured with multiple instruments.

Group data from different measurement locations, times, and dates into folders and view them together. Group together trend graphs for multiple data sets and output them as a report. This feature is useful when you wish to compare dates from a repeat recording run or data from multiple locations.

Display detailed measurement data, including event statistics, an event list, and event graphs. Simply choose the parameters you need to output to the report. Display statistics about events by date or time of day. This feature makes it easy to discover power supply anomalies that occur at particular times of day or on particular days of the week. Display statistics about events by date or time.

This feature makes it easy to discover anomalies that occur at particular times of day or on particular days of the week. Evaluate whether data complies with the EN standard by analyzing it and generating a judgment based on voltage fluctuations during the trend interval. You can also customize the judgment criteria and parameters.

Please contact your nearest Hioki distributor for connections exceeding Log into your myHioki account to access more technical documents and information where available. Kaohsiung Industrial Automation Exhibition - Taiwan. If you can not download, log into your myHioki account to access more technical documents and information where available.

For power or load current measurement 1 sensor necessary for single-phase measurements, and 2 or 3 sensors required for 3-phase measurements. When three-phase 3-wire connection, the voltage cord to be connected can be reduced from 6 to 3.

When three-phase 4-wire connection, the voltage cord to be connected can be reduced from 6 to 4. Banana branch-banana, Red: 1, 0.

Banana branch-banana, Black: 1, 0. Compatibility and performance are not guaranteed for SD cards made by other manufacturers. You may be unable to read from or save data to such cards. Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m Measure Transient Voltage Waveforms. Measure Periodical Instantaneous Voltage Drops. Overview Specifications Downloads Options Applications Gallery Hioki portable power meters and analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy.

Model No. Maintain and manage power supplies and analyze problems more easily and reliably than ever before The critical importance of electrical power in today's society necessitates daily maintenance and management to ensure that problems don't occur. Analyze equipment power problems Capture the full range of power supply anomalies, including momentary interruptions, voltage drops, and frequency fluctuations, while recording trends to help investigate the causes of unexpected equipment malfunctions and sudden stoppages.

Record quality data for power systems Record fluctuations in voltage, current, power, harmonics, and flicker when connecting a highly variable system such as a renewable energy source or EV charging station to the grid. Capture power anomalies reliably with simple settings The PQ and PQ can measure all parameters at once, including power, harmonics, and anomaly waveforms. Simultaneously record event waveforms and trend graphs When an event occurs, the instrument records the instantaneous waveform for 0.

International standard IEC Ed. High-voltage, wideband performance The PQ can measure transient voltages of up to V lasting as little as 0. Two-circuit measurement Since the PQ's fourth voltage channel is isolated from its first three voltage channels, the instrument can measure power and efficiency across two separate circuits. Verify the quality of power supplied by an EV rapid charger Since the PQ's fourth voltage channel is isolated from its first three voltage channels, the instrument can measure power and efficiency across two separate circuits.

Simple inverter measurement The PQ can measure the secondary side of inverters with a fundamental frequency of 40 to 70 Hz and a carrier frequency of up to 20 kHz. Wide array of ranges to accommodate all applications Use HIOKI sensors in an array of applications to measure equipment ranging from the secondary side of CTs to high-current wiring.

Easy-to-understand display of parameters Since you can switch the display to show all measurement parameters while measurement is underway, it's easy to check conditions.

Automatic sensor detection to avoid erroneous measurement Simply connect current sensors, touch "Sensor" on the screen, and the instrument will automatically detect sensor types and maximum current ranges. Simple setup functionality for simplified configuration of recording parameters Simply choose the preset that suits your application, and the instrument will automatically configure the recording parameters.

Event list Display statistics about events by date or time of day. Event statistics Display statistics about events by date or time. EN judgment function Evaluate whether data complies with the EN standard by analyzing it and generating a judgment based on voltage fluctuations during the trend interval. Basic specifications Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year Measurement line type Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel for voltage, current, power measurement AC or DC measurement Voltage ranges Voltage measurement: Transient voltage : 2 MHz sampling 2.

Frequency cycle : Calculated as one cycle, 40 to 70 Hz 3. Voltage swell, Voltage dips, Voltage interruption 5. Inrush current 6. Voltage waveform comparison 7. Instantaneous flicker value: As per IEC 8. Voltage waveform peak, Current waveform peak Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Reactive energy, Power factor, Displacement power factor, Voltage unbalance factor, Current unbalance factor, and efficiency Harmonic voltage-current phase angle: 1th to 50 th orders K Factor multiplication factor Seminar Videos On Demand No results were found.

Manuals If you can not download, log into your myHioki account to access more technical documents and information where available. Outline Drawings If you can not download, log into your myHioki account to access more technical documents and information where available.

Technical Notes No results were found. Others No results were found. Z hang the cords on the metal surface. Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel for voltage, current, power measurement AC or DC measurement. PQ ONE.

KLX300R MANUAL PDF

Hioki 3198 user manual

Hioki Pw Manual is an easy- to- use program that will help you learn about your fertility signs through documentation of your observations. The number of hioki power supply problems is increasing as power systems are becoming more and more complicated - all due to the rising use of power electronics devices plus a growing installed base of large systems and distributed power supplies. This unit comes with probes and manual. Overview The is a pencil- shaped digital hioki user manual multimeter hioki user manual designed to measure DC AC voltage and resistance. When The Mother and Marshall are driving. Before measurement 1 Getting For more information.

ESCRIA DE ACIARIA PDF

Hioki PW3198 Manual

.

HEEKSCAD MANUAL PDF

Hioki PW3198 Instruction Manual

.

Related Articles